ESOR=0, STPE=0, TSIEN=0, TSIIEN=0, DVOLT=00, STM=0, SCNIP=0, EOSF=0, EOSDMEO=0
TSI General Control and Status Register
EOSDMEO | End-of-Scan DMA Transfer Request Enable Only 0 (0): Do not enable the End-of-Scan DMA transfer request only. Depending on ESOR state, either Out-of-Range or End-of-Scan can trigger a DMA transfer request and interrupt. 1 (1): Only the End-of-Scan event can trigger a DMA transfer request. The Out-of-Range event only and always triggers an interrupt if TSIIE is set. |
EOSF | End of Scan Flag 0 (0): Scan not complete. 1 (1): Scan complete. |
SCNIP | Scan In Progress Status 0 (0): No scan in progress. 1 (1): Scan in progress. |
STM | Scan Trigger Mode 0 (0): Software trigger scan. 1 (1): Hardware trigger scan. |
STPE | TSI STOP Enable 0 (0): TSI is disabled when MCU goes into low power mode. 1 (1): Allows TSI to continue running in all low power modes. |
TSIIEN | Touch Sensing Input Interrupt Enable 0 (0): TSI interrupt is disabled. 1 (1): TSI interrupt is enabled. |
TSIEN | Touch Sensing Input Module Enable 0 (0): TSI module disabled. 1 (1): TSI module enabled. |
CLKSOC_SEL | CLKSOC_SEL |
RUN_CTRL | RUN_CTRL |
TSI_ANA_TEST | TSI_ANA_TEST |
DVOLT | DVOLT 0 (00): Vm=0.3V; Vp=1.3V; dvolt=1.0V. 1 (01): Vm=0.3V; Vp=1.6V; dvolt=1.3V. 2 (10): Vm=0.3V; Vp=1.9V; dvolt=1.6V. 3 (11): Vm=0.3V; Vp=2.3V; dvolt=2.0V. |
ESOR | End-of-scan or Out-of-Range Interrupt Selection 0 (0): Out-of-range interrupt is allowed. 1 (1): End-of-scan interrupt is allowed. |
OUTRGF | Out of Range Flag. |